All Support
Support Tool

Wire Speed
Calculator

Enter the display value shown on your TIP TIG control panel to calculate the actual wire feed speed in m/min and IPM.

Old TIP TIG Control Panel

Old Control Panel

For the original TIP TIG control panel with analog dial display.

m/min—
IPM—

Formula: m/min = Display × 0.0635  |  IPM = Display × 2.5

The wire feed speed may have a variation of ± 5%. It depends on the feed roll tensioner's settings and the wire's quality.

How the calculator works

The TIP TIG control panel shows a display value. The calculator converts it into the actual wire feed speed in m/min and IPM. Choose the tab that matches your control panel, then enter the value.

Example, new control panel: a display value of 100 gives 100 × 0.0657 + 0.17 = 6.74 m/min (265 IPM).
Example, old control panel: a display value of 100 gives 100 × 0.0635 = 6.35 m/min (250 IPM).

Frequently Asked Questions

Questions about the calculator

Which control panel do I have?
The original control panel has an analog dial display, the current one a digital display. The control panel guide shows both.
How accurate is the result?
The wire feed speed may have a variation of ± 5%. It depends on the feed roll tensioner’s settings and the wire’s quality.